목록전체 글 (806)
temperature measurement -200°C to 1400°Ctemperature recording with a resolution of 0.1°C in the range of -200°C to 1000°C in the remaining 1°Caccuracy 0.6°C in the range from -10°C to 150°C:registration is signaled with the LOG sign on the displaydisplaying information about exceeded permissible valuesstart directly from the computer with a time delay or START/STOP from the buttonrecording frequ..
Sample ConcentratorNeedles or glass pipets blow gas onto the surface of the solutionrapid evaporation of the solvent.Temperature range up to 150 degBlowing a large number of samples at one timeBlowing each sample independently.Amount of airflow can be adjustedTimer up to 99hours 59minNitrogen consuption:0-10L/minIncludes 50 needles of 150 mm lengthDimentions (mm): L 280 x W 240 x H 110Optional b..
Heat/Cool 2X 175liter -10 to 60 deg C dual chamber laboratory incubatorDigital PID controlForced air circulationInternal:w60xd50xh50cmExternal:w68xd71xh84cm,77kgHeater: Incubator 500WRefrigerator 1/5 HP2 shelves for each incubatorPower supply 110/220V (8A)Weight 200kgSafety devicesShort circuit breaker, overheat protector refrigerator overload protector,sensor abnormality, over low protector±0.5..
Test tube rocker for laboratoryHolds up to 16 tubes 10mlHolds up to 30mm tube diameter and 110mm longPlatform size: W300xD115 mmEasy to clean removable rubber padTilt angle30±3°Load capacity1kgMotor typeBrushless DC motorSpeed range[rpm]0~30Operation modeContinuousDimension (W×D ×H)405×160×120mmVoltage100~240V, 50/60HzPower15WWeight2kgPermissible ambient temperature and humidity5~40℃, 80% Test t..
Temp. Control Range: RT+5°C~100°CTouch screen,60 user programable settingsHeating lid,block not includedStability @ 100°C: ±0.4°CUniformity: within the block @ 37°C: ±0.2°Cacross similar blocks @ 37°C;±0.3°CDisplay Accuracy/Display: 0.1 “C/Touch ScreenHeating Time (25°C to 100°C) 15minTiming Range 1 min-99h59minDimensions (L×W×H)mm 380×210×160Weight 5.5kg Two blocks dry bath incubator with progr..
Titan Hotplate dimensionsmm x mm280 x 200Constant heating surfacemm x mm230 x 160Maximum temperature°C600PowerWatt2000Temperature distributionK± 2Cable length (standard)m1,5Outer dimensionsmm x mm350 x 300Height withou lidmm110Height with lidmm145Not include temp controlInclude lidPower 230volt,2000wattOptional temperature controller or programmer High temp. titanium hotplate up to 600°C,With co..
ample Capacity: 96*0.1 ml PCR plate, 12*8-strip tubes, 96*0.1 ml single tube (Transparent Cover)Reaction System: 10 - 50μlDynamics Range: 1-1010 copiesTemp. control range / Emission: Light 4 / LEDExcitation Wavelength: 455~680nmDetection Wavelength: 510~730nmRamp Rate: 5.0°C/s(max)Gradient Temp. / Hot-Lid Temp. Range: 1-36°C / 100°C, Automatic Hot-lidScanning Mode: Full plate scanning Fluorescen..
Temperature rangeRoom temp.+50C - 3000CMeasuring range0.1-100%Temperature accuracy±1°CReproducibilityRelative error 1%Capacity per batch6pcs./batchSample weight0.5-15gSolvent cup volume150mlSolvent recovery>85%Power supply220VAC±10%, 50HzPower2.6KWDimensions650mmx380mmx720mmNet Weight50Kg Auto Fat Analyzer: Soxhelt extraction method, FA-6 더 자세한 정보는 켐코코리아로 문의하세요~!켐코코리아 주식회사Tel. 043-215-2012e-mail..
Vacuum filtration ,complete set, 3 places+Torch Burner - includes :* vp-34, Oil Free Vacuum Pump* 3-Places StainlessSteel Manifold* 100ml S.S. filter funnel, 3pcs* 4000 ml PP Waste Bottle with drain* Dragon 100, Torch Burner* MCE Membrane, 47 mm, 0.45 μm, 200/PK* Silicone Tube (2m)◆ Max. flow rate: 34 l/min◆ Max. vacuum: -680 mmHg◆ Waste bottle: 4000 ml, made of PPwith drain◆ Number of branch: ..
CVP-14-300A is ideal for the sample pretreatment ofHPLC, GC, AA etc. In microanalysis or the purification ofsolvents etcInclude:CVP-14 Chemical resistant vacuum pumpVF 3 filtration set, PTFE disc filter (0.2μm),1m Silicone tubeEffective filtration area: 9.6 squared cmAcid,alkali & organic japor resistantPower 60watt 1/8 horsepowerExternal size: W275x H165x D150 mmMax. flow rate:20 l/minMax. vacu..
Digital Dry cabinet 1-10%RH, 1428 literThermoelectric drying systemInternal: W1198xD680xH1738mmExternal: W1200xD700xH1920 mm,120kgUsed to store:optical,medicines and chemicals, electric componentsSteel case, glass door+key,5 shelvesBlack is ESD safe, white is Non-ESD safeThe maximum load for each shelf is 50 kg Dry cabinet 1-10%RH 1428 liter 5 Shelves 6 Doors, DYCDE-1428-6-W 더 자세한 정보는 켐코코리아로 문의하..
● Auto Kjeldahl method Analyzer for nitrogen determination● Automatic integrating distillation and titration fuctions, calcultion and printing● Automatic waste dicharge and cleaning of boiling tubes and titration cups.● Control steam supply real-Time detection of condensation temperature.● High sensibility color sensing unit ensures accurate final point determination● Burette volume: 1.0 micro L..