FeaturesInfinity TestAuthority checksDevice checksAccurate and Complete Copies of RecordsMulti-Level SecurityElectronic Log BookAudit TrailReportMetadata StorageLANTouch screenFingerprint Authentication 7" TFT touch screen displayLAN connectivity allows central printingMultilevel security with password for 250 users with user programmable roleAlphanumeric data entry of product and user details..
temperature measurement -200°C to 1400°Ctemperature recording with a resolution of 0.1°C in the range of -200°C to 1000°C in the remaining 1°Caccuracy 0.6°C in the range from -10°C to 150°C:registration is signaled with the LOG sign on the displaydisplaying information about exceeded permissible valuesstart directly from the computer with a time delay or START/STOP from the buttonrecording frequ..
Sample ConcentratorNeedles or glass pipets blow gas onto the surface of the solutionrapid evaporation of the solvent.Temperature range up to 150 degBlowing a large number of samples at one timeBlowing each sample independently.Amount of airflow can be adjustedTimer up to 99hours 59minNitrogen consuption:0-10L/minIncludes 50 needles of 150 mm lengthDimentions (mm): L 280 x W 240 x H 110Optional b..
Heat/Cool 2X 175liter -10 to 60 deg C dual chamber laboratory incubatorDigital PID controlForced air circulationInternal:w60xd50xh50cmExternal:w68xd71xh84cm,77kgHeater: Incubator 500WRefrigerator 1/5 HP2 shelves for each incubatorPower supply 110/220V (8A)Weight 200kgSafety devicesShort circuit breaker, overheat protector refrigerator overload protector,sensor abnormality, over low protector±0.5..
Test tube rocker for laboratoryHolds up to 16 tubes 10mlHolds up to 30mm tube diameter and 110mm longPlatform size: W300xD115 mmEasy to clean removable rubber padTilt angle30±3°Load capacity1kgMotor typeBrushless DC motorSpeed range[rpm]0~30Operation modeContinuousDimension (W×D ×H)405×160×120mmVoltage100~240V, 50/60HzPower15WWeight2kgPermissible ambient temperature and humidity5~40℃, 80% Test t..
Temp. Control Range: RT+5°C~100°CTouch screen,60 user programable settingsHeating lid,block not includedStability @ 100°C: ±0.4°CUniformity: within the block @ 37°C: ±0.2°Cacross similar blocks @ 37°C;±0.3°CDisplay Accuracy/Display: 0.1 “C/Touch ScreenHeating Time (25°C to 100°C) 15minTiming Range 1 min-99h59minDimensions (L×W×H)mm 380×210×160Weight 5.5kg Two blocks dry bath incubator with progr..
Titan Hotplate dimensionsmm x mm280 x 200Constant heating surfacemm x mm230 x 160Maximum temperature°C600PowerWatt2000Temperature distributionK± 2Cable length (standard)m1,5Outer dimensionsmm x mm350 x 300Height withou lidmm110Height with lidmm145Not include temp controlInclude lidPower 230volt,2000wattOptional temperature controller or programmer High temp. titanium hotplate up to 600°C,With co..
ample Capacity: 96*0.1 ml PCR plate, 12*8-strip tubes, 96*0.1 ml single tube (Transparent Cover)Reaction System: 10 - 50μlDynamics Range: 1-1010 copiesTemp. control range / Emission: Light 4 / LEDExcitation Wavelength: 455~680nmDetection Wavelength: 510~730nmRamp Rate: 5.0°C/s(max)Gradient Temp. / Hot-Lid Temp. Range: 1-36°C / 100°C, Automatic Hot-lidScanning Mode: Full plate scanning Fluorescen..
Temperature rangeRoom temp.+50C - 3000CMeasuring range0.1-100%Temperature accuracy±1°CReproducibilityRelative error 1%Capacity per batch6pcs./batchSample weight0.5-15gSolvent cup volume150mlSolvent recovery>85%Power supply220VAC±10%, 50HzPower2.6KWDimensions650mmx380mmx720mmNet Weight50Kg Auto Fat Analyzer: Soxhelt extraction method, FA-6 더 자세한 정보는 켐코코리아로 문의하세요~!켐코코리아 주식회사Tel. 043-215-2012e-mail..
Vacuum filtration ,complete set, 3 places+Torch Burner - includes :* vp-34, Oil Free Vacuum Pump* 3-Places StainlessSteel Manifold* 100ml S.S. filter funnel, 3pcs* 4000 ml PP Waste Bottle with drain* Dragon 100, Torch Burner* MCE Membrane, 47 mm, 0.45 μm, 200/PK* Silicone Tube (2m)◆ Max. flow rate: 34 l/min◆ Max. vacuum: -680 mmHg◆ Waste bottle: 4000 ml, made of PPwith drain◆ Number of branch: ..
CVP-14-300A is ideal for the sample pretreatment ofHPLC, GC, AA etc. In microanalysis or the purification ofsolvents etcInclude:CVP-14 Chemical resistant vacuum pumpVF 3 filtration set, PTFE disc filter (0.2μm),1m Silicone tubeEffective filtration area: 9.6 squared cmAcid,alkali & organic japor resistantPower 60watt 1/8 horsepowerExternal size: W275x H165x D150 mmMax. flow rate:20 l/minMax. vacu..
Digital Dry cabinet 1-10%RH, 1428 literThermoelectric drying systemInternal: W1198xD680xH1738mmExternal: W1200xD700xH1920 mm,120kgUsed to store:optical,medicines and chemicals, electric componentsSteel case, glass door+key,5 shelvesBlack is ESD safe, white is Non-ESD safeThe maximum load for each shelf is 50 kg Dry cabinet 1-10%RH 1428 liter 5 Shelves 6 Doors, DYCDE-1428-6-W 더 자세한 정보는 켐코코리아로 문의하..