목록분류 전체보기 (679)
Section Thickness Setting Range 0.25—100μm 0.25—2.5μm increment 0.25μm 2.5—5μm increment 0.5μm 5.0—10μm increment 1μm 10—30μm increment 2μm 30—60μm increment 5μm 60—100μm increment 10μm Trimming Thickness Setting Range: 1—600μm 1—10μm increment 1μm 010—020μm increment 2μm 020—050μm increment 5μm 050—150μm increment 10μm 150—600μm increment 50μm Retraction Setting Range: 0—50μm ( 0 is off ) 5-10-..
Number of effective pixels16.1 million Image sensor-2.3/1in. type CMOS; approx. 16.76 million total pixels LensNIKKOR lens with 60x optical zoom Focal length258-4.3 mm (angle of view equivalent to that of 1440-24 mm lens in 35mm [135] format) f/-numberf/6.5-3.3 Construction16 elements in 11 groups (4 ED lens elements and 1 super ED lens element) Digital zoom magnificationUp to 4x (angle of view ..
Homogenizer with stand For manual use and table use Speed range:up to 26,000rpm Capacity:0.3 up to 3,000ml Over heat protector Power 250 watt Generators are not included Stand size:w200Xd315Xh500mm HOMOGENIZER 250WATT WITH STAND (BODY ONLY) 26,000RPM : HOG-020 더 자세한 정보는 켐코코리아로 문의하세요~! 켐코코리아 주식회사 Tel. 043-215-2012 e-mail. ck@chemcokorea.com Web. http://www.chemcokorea.com/ Blog. http://blog.chemc..
Foot pedal: Standard (Flame during pressed foot pedal, Foot pedal optional) Flame temperature: 1200C liquid gas, 1170C on natural gas Temp. threshold level: 0.66 kW liquid gas, 0.66 kW natural gas Burner tube: removable, stainless steel Adjustable flame Size:(WXHxD) 89x34x88mm LAB SAFETY GAS BURNER : Flame100 더 자세한 정보는 켐코코리아로 문의하세요~! 켐코코리아 주식회사 Tel. 043-215-2012 e-mail. ck@chemcokorea.com Web. h..
Speed Range 4.0m/s - 7.0m/s (in steps of 0.05m/s) Cycle Duration 1~90s (in steps of 1s) Pause Time 0~2 minutes Acceleration ≤2 sec. to max. speed Deceleration ≤2 sec. to stop Programmable 50 Saved Programs Number of Cycles 10 Rotors not included Display O-LED, High light and no visual angle limit Number of Samples 1~24 samples Running Noise < 68db Weight 25kg Dimensions (WxDxH) 280mm x 360mm x 3..
Temperature rangeRoom temp.+50C - 3000C Measuring range0.1-100% Temperature accuracy±1°C ReproducibilityRelative error 1% Capacity per batch6pcs./batch Sample weight0.5-15g Solvent cup volume150ml Solvent recovery>85% Power supply220VAC±10%, 50Hz Power2.6KW Dimensions650mmx380mmx720mm Net Weight50Kg AUTO FAT ANALYZER : SOXHELT EXTRACTION METHOD : FA-6 더 자세한 정보는 켐코코리아로 문의하세요~! 켐코코리아 주식회사 Tel. 043..
Dissolution Tester include: 6 x Round bottom flack 6 x Cover of bottom flack 6 x Rotation shaft 6 x Rotation basket 6x Paddle shaft 6 x Sinker Speed (rpm) 10~220 rpm Electric control stepless speed control Low water/Over heat protectors Digital temperature control The temperature control range is RT +5.0~50 ± 0.5 ℃. The round bottom flask volume is 1L each. Heater 900watt Water circulation tank ..
22 liter natural convection Portable laboratory incubator Digital temperature control Ambient - 15 oC to 60 oC Compact footprint, usable on small bench space Accepts multiple types of flasks up to 2L Internal power outlet for installing small shaker, mixer or other instruments Temperature accuracy 0.5 °C (at 37 °C) No calibraion procedure Temperature uniformity is 1.5°C Temperature Increments 1°..
Multimagnetic stirrer: Provides 6 individually stirring positions Stirs up to 8 liter water Speed range:up to 1300rpm Dimensions: W80xH10xD13cm MULTIMAGNETIC STIRRER 6 PLACES : F 13-6 더 자세한 정보는 켐코코리아로 문의하세요~! 켐코코리아 주식회사 Tel. 043-215-2012 e-mail. ck@chemcokorea.com Web. http://www.chemcokorea.com/ Blog. http://blog.chemcokorea.com/
12 channels Temperature recorder SD card data logger. Data can be down load to the Excel, extra software is no need * Auto datalogger or manual datalogger. data and LCD Backlight is OFF) : Data logger sampling time range : 1 to 3600 seconds. * Sensor type: J/K/T/E/R/S thermocouple. Optional Accessories : * Type K thermocouple probe CAT # : TP-01, TP-02A. TP-03, TP-04 * SD Card * USB cable, USB-0..
Dispenser for Bottles - 1 - 10ml Without Re-circulation valve DISPENSER FOR BOTTLES 1-10ML : BDI-A-10 더 자세한 정보는 켐코코리아로 문의하세요~! 켐코코리아 주식회사 Tel. 043-215-2012 e-mail. ck@chemcokorea.com Web. http://www.chemcokorea.com/ Blog. http://blog.chemcokorea.com/
● Auto Kjeldahl method Analyzer for nitrogen determination ● Automatic integrating distillation and titration fuctions, calcultion and printing ● Automatic waste dicharge and cleaning of boiling tubes and titration cups. ● Control steam supply real-Time detection of condensation temperature. ● High sensibility color sensing unit ensures accurate final point determination ● Burette volume: 1.0 mi..